NaI(Tl) Detector(PMT Readout)

 

Advantage

1.High light output

2.High detection efficiency

3.Low cost

4.Good
high temperature resistance 

5. FWHM 7%

 

Description
  • Detector 1

    Introduction
    KHD-1 scintillation
    detector is a new generation γ-ray measurement device. Combined with lead
    chamber and Multi-channel Analyzer(MCA) to form Energy Spectrometer, widely
    used in weak radioactivity analysis field, such as building materials, food, geology
    etc.

    KHD-1 scintillation detector’s advantage including compact structure,easy operation,low background,excellent energy resolution,stable output,high reliability,durability and high detection efficiency.

    Properties

    Specification

    Range

    Unit

    Scintillator
    Effective Size

    φ50 X 50

    mm

    Input
    Voltage

    11.5 ~12.5

    V

    Input
    Current

    60

    mA

    Output
    Polarity

    Positive Polarity

    Output
    Amplitude (MAX)1

    9

    V

    Output
    Amplitude
    TYPE2

    1

    V

    ResolutionCs1373

    8.5

    %

     Background Count Rate30kev~3Mkev

    250

    min-1

    Work
    Temperature

    0 ~ +40

    Storage
    Temperature

    -20 ~ 55

    Humidity

    90

    %

    Notes:
    1.Detector signal exceeds this value, a
    truncation will occur.
    2.
    The amplitude of signal is usually less than
    1V in spectrum analysis.
    3.
    The value is measured when detector
    preheated for 10 minutes, the counting rate within 1000, total counting number
    is  less than 10
    5 in Cs137 peak.

     

    Working Principle

    Interface

    Interface

    Wiring

    Wiring Definition

    BNC

    Coaxial
    Cable

    Signal Line

    DB9

    Triple-core Shielding Wire

    2:+12V5:-12V9:GND

    SHV

    Single-core Shielding Wire

    High Voltage 0 ~ 1250V

    Detector 2

    Introduction

    KHD-2 scintillation
    detector is another generation γ-ray measurement device. Combined with lead
    chamber and Multi-channel Analyzer(MCA) to form Energy Spectrometer, widely
    used in weak radioactivity analysis field, such as building materials, food, geology
    etc.
    KHD-1 scintillation detector’s advantage including compact structure,easy operation,low background,excellent energy resolution,stable output,high reliability,durability and high detection efficiency.

    Properties

    Specification

    Range

    Unit

    Scintillator
    Effective Size

    φ50 X 50

    mm

    Input
    Voltage

    11.5 ~12.5

    V

    Input
    Current

    60

    mA

    Output
    Polarity

    Positive Polarity

    Output
    Amplitude (MAX)1

    9

    V

    Output
    Amplitude
    TYPE2

    1

    V

    ResolutionCs1373

    8.5

    %

     Background Count Rate30kev~3Mkev

    250

    min-1

    Work
    Temperature

    0 ~ +40

    Storage
    Temperature

    -20 ~ 55

    Humidity

    90

    %

    Notes
    1.Detector signal exceeds this value, a
    truncation will occur.
    2.
     The amplitude of signal is usually less than
    1V in spectrum analysis.
    3.
    The value is measured when detector
    preheated for 10 minutes, the counting rate within 1000, total counting number
    is less than 10
    5 in Cs137 peak.

    Working Principle
    Interface

    Interface

    Wiring

    Wiring Definition

    BNC

    Coaxial Cable

    Signal Line

    DB9

    Triple-core Shielding Wire

    2:+12V5:-12V9:GND

    Notes

    High
    Voltage should be set before putting on the market, without regulation function.

     